Common faults and solutions of multi gradient experimental tube furnace

Time:2025-04-08 10:29:11 Click:0
  The multi gradient experimental tube furnace may encounter some common faults during operation, and the following are these faults and their solutions: 1. Power on and power supply issues Instrument without power display Possible reasons: improper plug insertion, blown fuse, blown control circuit fuse. Solution: Check if the plug is plugged in or connected properly, replace the fuse, check for short circuits and eliminate them before replacing the fuse. The power supply and heating elements are normal, but the temperature inside the furnace does not rise Possible reasons: Low set temperature, damaged control circuit. Solution: Adjust the set temperature. If the control circuit is damaged, notify professional maintenance personnel for inspection. 2. Temperature control issues The set temperature does not match the temperature inside the furnace Possible reasons: Damage to temperature sensors or temperature controllers, deviation between temperature measurement points and layout points. Solution: Replace the temperature sensor or thermostat and position it correctly. The instrument is outputting normally, but the OUT indicator light is not flashing Possible cause: The main circuit has malfunctioned. Solution: Check if the resistance wire is short circuited and if the heating element is controllable. If it is not controllable, it is recommended to replace the temperature controller or resistance wire. During the heating process, the temperature does not rise but instead decreases Possible reason: The positive and negative poles of the thermocouple are reversed. Solution: Replace the thermocouple connector. Over temperature alarm Possible reason: The temperature inside the furnace exceeded the limit, and the instrument acted as a protective measure. Solution: Wait until the temperature drops to a safe level before the instrument returns to normal. 3. Vacuum degree issue The vacuum degree decreases when using vacuum pumping Possible reasons: aging or damage of the heat-resistant silicone ring between the stainless steel flanges, and leakage of the vacuum system. Solution: Replace the heat-resistant silicone ring, reinstall the stainless steel flange, or replace and repair the vacuum system. 4. Other common questions The ammeter has no current, but the voltmeter has voltage Possible cause: Heating element breakage. Solution: Replace the broken heating element according to the instructions. The voltage and power supply are normal, but the equipment is not working Possible cause: Incorrect parameter settings for the rotary furnace. Solution: Notify the manufacturer to set the correct parameters.

Inquiry

Please leave a message here. We will reply you in 24 hours.

Contact Information

E-mail:
web@kejiafurnace.com
Address:
Room 1505, Building 9, No. 26 Dongqing Street, High-tech Industrial Development Zone, Zhengzhou City, Henan Province
QQ tel Email WhatApp FaceBook

Tel Number

+8618037178440

Email

web@kejiafurnace.com

WhatsApp

+8618037178440

FaceBook

Zhengzhou/Kejia

kejialiuyan