The temperature of the high-temperature graphite vacuum furnace cannot rise

Time:2025-09-18 13:11:06 Click:0
  The temperature of the high-temperature graphite vacuum furnace cannot rise, which may be caused by power failure, damaged heating elements, insufficient vacuum degree, temperature control system failure, or cooling system problems. The following are specific analysis and solutions: Power failure Possible reasons: power line malfunction, switch damage, or insufficient power supply. Diagnostic method: Check if the power lines and switches are functioning properly, ensuring there are no open or short circuits. Use a multimeter to check the output voltage and current of the power supply to ensure normal power supply. Heating element damaged Possible reasons: Heating element aging, breakage, or poor connection. Diagnostic method: Use a multimeter to check the resistance value of the heating element and determine if the heating element is damaged. Check whether the connection of the heating element is firm, without looseness or detachment. If the heating element is damaged, it is necessary to replace it with a new one in a timely manner. Insufficient vacuum degree Possible reasons: vacuum pump malfunction, aging or damaged seals, pipeline blockage, etc. Diagnostic method: Check the operation status and sound of the vacuum pump to ensure that it can work properly. Observe whether the seal is aging or damaged, and replace it promptly if it is damaged. Check the vacuum degree with a vacuum gauge and ensure that the pipeline is unobstructed to ensure no leakage. Temperature control system malfunction Possible reasons: temperature controller malfunction, thermocouple failure, or incorrect parameter settings. Diagnostic method: Use a multimeter to check if the resistance value of the thermocouple is normal and determine if the thermocouple is damaged. Check if the setting parameters of the thermostat are correct to ensure that the thermostat can work properly. If the thermostat or thermocouple malfunctions, it needs to be repaired or replaced in a timely manner. Cooling system issues Possible reasons: Insufficient cooling water supply, blocked cooling system, or faulty cooling fan. Diagnostic method: Check if the cooling water pipeline is unobstructed to ensure sufficient cooling water supply. Clean the blockage in the cooling system, such as scale, impurities, etc. Check the operation status and sound of the cooling fan to ensure that it can work properly.

Inquiry

Please leave a message here. We will reply you in 24 hours.

Contact Information

E-mail:
web@kejiafurnace.com
Address:
Room 1505, Building 9, No. 26 Dongqing Street, High-tech Industrial Development Zone, Zhengzhou City, Henan Province
QQ tel Email WhatApp FaceBook

Tel Number

+8618037178440

Email

web@kejiafurnace.com

WhatsApp

+8618037178440

FaceBook

Zhengzhou/Kejia

kejialiuyan